InstallationandOperationManual(REVH) PVI6500/PVI7500
43
3seconds
↓
Thefirst twomessages areabout the PV array and output voltagesandpower.Vpvis the incoming DC voltage fromthe PV
array.Wpv is the incoming power of the PV array in Watts.Vac, Pac, Iac, and Fac are the voltage, power, current, and
frequency
attheinverteroutput.
3seconds
↓
3seconds
↓
3seconds
↓
ThenextmessageshowstheaccumulatedenergyinkWhandnumberofrunninghourssincetheinverterhasbeenpoweredon
fortheday.
3seconds
↓
Thenextmessageshowsthetotalaccumulatedenergyin
kWhandperiodoftimeinhourssincetheinverterhasbeeninstalled
andoperatedforthefirsttime.
3seconds
↓
PowerDeratingMessage
Therearefivepossiblederatingmessageswhichwillbeshownifthepowerisderatedduringgridfeedingmode.Onlyonede‐
ratingcauseisdisplayedatatime.When“Temp”messageispresent,thepowerderatingiscausedbyanovertemperatureof
theheatsink.The“Ipv”messageshows
thatthepowerderatingiscausedbyrestrictingtheDCinputcurrenttothemaximum
limit. The “Iac” and “Pac” messages illustrate the power derating is caused due to a restriction of the maximum output AC
currentandpower.The“VacH”messageshowsthatthepowerderatingiscausedby
highACvoltage.
M o de
G r id/MPP
V p v XXXV
W p v XXXXW
V a c XXX . XV
P a c XXXXW
F a c X X . X H z
I a c X X . X A
E t o d a y XXX . X kWh
H t o d a y X X . X H r
E a c XX XXXX . X kWh
H XXXXX H r